We manufacture steam sterilizers / autoclave from highly sophisticated and innovative processes. We design these sterilizers as per the ASME standards. These sterilizers are used across various industries like pharmaceutical, food processing, chemical, beverage etc. These are available in the following models as per their usage:
* Vertical sterilizers with swing doors
* Bung processor cum sterilizer
* Horizontal cylindrical sterilizers with conventional radial arm
* Horizontal rectangular sterilizers with conventional radial arm and with sliding door
Salient Features:
* Specially designed chamber for ensuring complete removal of condensate
* Specially designed connectors and nozzles to avoid contamination
* Welded carefully to avoid depressions inside the chamber
* Even distribution of steam
* Sterile air filter (0.01micron) for vacuum break is available on the sterile side of the
Steam Indicator Strips
Directons for Use of Steam Indicator Strips:
Each strip is a sticker, provided with a upper half green color & lower half blank to write.
> Do not handle the green portion to avoid staining.
> Please use ball pen only when writing details.
> Write place, date & type of sterilization equipment, you are using (Autoclave / Portable Pressure Cooker / Sterilizer) on Indicator Label.
> Stick or place the Indicator Label on the upper portion of the dressing drum in case of autoclaving OR On the upper side portion of the upper rack in case of portable pressure sterilizer (Pressure Cooker).
> For the first time do the sterilization as you are doing routinely. Note the time in minutes you had continued after required pressure built up.
> After sterilization is completed allow the autoclave / pressure sterilizer to cool down.
> Note the color of the upper green portion of the Indicator if turned Black/Grey or not, if this has changed to Black/Grey color, this indicates that the sterilization cycle was proper.
> The autoclaving cycle should be followed in this manner - Start the autoclave with instruments & other items, allow the autoclave to reach the pressure 15 lbs/sq. inch visible from the guage mounted on the lid. In case of protable pressure sterilizer a whistle will be heard then maintain the pressure for 25-30 minutes, switch off stove and allow cool down the sterilizer.
> Please keep the lables in cool & dry place in the plastic bag provided till their use.